Input reading

Be notified if the door opens!

Input reading

Two inputs are available to read the status of switches/signals/buttons/levels etc.

It is possible to read two signals and automate actions based on their status.

These signals are read via pins 10 and 11 and can be:

  • Switches/Buttons to Positive
  • Switches/Buttons to the negative
  • Enable signals from equipment

Input reading

The same inputs are available in CamperCheck 3B

The CamperCheck 3B input pins are available on pins 7 and 8.

CamperCheck Presentation

To get a more complete idea of how CamperCheck works you can go to the YouTube channel.

In the video on this page you can see how to use CamperCheck to read inputs and in particular to use it as ANTI-THEFT for the Camper.

Periodically the channel is updated with new videos, you can subscribe to stay updated.

Reading towards the positive

Button or switch

It is possible to read the status of a button or switch that closes the contact to the battery positive simply by connecting it as shown in the figure.

Reading towards the negative

Button or switch

It is possible to read the status of a button or switch that closes the contact to the battery negative, but in this case it will be necessary to enable the internal DIP SWITCH relating to the channel you wish to use in this way. See details

Readout of enable signal

Output of a device

It is possible to read the enable signal of any device by connecting it directly to the relevant input.

The accepted voltage levels are :

H : >2.2V max 36V DC

L: <2.2V DC

Connection examples

Do you have doubts about installation?

Contact us we will be happy to help you