Input reading
Two inputs are available to read the status of switches/signals/buttons/levels etc.
It is possible to read two signals and automate actions based on their status.
These signals are read via pins 10 and 11 and can be:
- Switches/Buttons to Positive
- Switches/Buttons to the negative
- Enable signals from equipment
Input reading
The same inputs are available in CamperCheck 3B
The CamperCheck 3B input pins are available on pins 7 and 8.
CamperCheck Presentation
To get a more complete idea of how CamperCheck works you can go to the YouTube channel.
In the video on this page you can see how to use CamperCheck to read inputs and in particular to use it as ANTI-THEFT for the Camper.
Periodically the channel is updated with new videos, you can subscribe to stay updated.
Reading towards the positive
Button or switch
It is possible to read the status of a button or switch that closes the contact to the battery positive simply by connecting it as shown in the figure.
Reading towards the negative
Button or switch
It is possible to read the status of a button or switch that closes the contact to the battery negative, but in this case it will be necessary to enable the internal DIP SWITCH relating to the channel you wish to use in this way. See details
Readout of enable signal
Output of a device
It is possible to read the enable signal of any device by connecting it directly to the relevant input.
The accepted voltage levels are :
H : >2.2V max 36V DC
L: <2.2V DC